Welcome: Dongguan Jianlong Hydraulic Machinery Co., LTD
lifuyan45@gmail.com 18988729072

Industry news

Common faults and maintenance methods of hydraulic solenoid valve

1. The solenoid valve does not work


Fault phenomenon: After the solenoid valve receives the electrical signal, the spool does not move.


Cause analysis: It may be due to solenoid valve coil break, valve core stuck, oil viscosity is too high resulting in poor flow and other reasons.


Maintenance method: Check whether the solenoid valve coil is broken, clean the spool, and replace the appropriate oil.


2. The solenoid valve works abnormally


Fault symptom: The solenoid valve is slow, insensitive or jitter.


Cause analysis: It may be due to the blockage of the valve port, gas in the oil, insufficient electromagnetic force and other reasons.


Maintenance method: Clean the valve port, remove the gas in the oil, and check whether the electromagnet works normally.


3. The solenoid valve leaks oil


Fault phenomenon: Oil leakage from the solenoid valve inside.


Cause analysis: It may be due to aging of sealing ring, spool wear and other reasons.


Repair method: Replace the seal ring, repair or replace the spool.


Hydraulic press, stamping machine, forming machine, forging machine, cold extrusion forming machine


CATEGORIES

CONTACT US

Contact: Jessie

Phone: 18988729072

E-mail: lifuyan45@gmail.com

Whatsapp:+8618988729072

Add: Guangyi Industrial Park, No.2 Jinfu West Road, Tanglip, Liaobu Town, Dongguan City, Guangdong Province, China